Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
The Treatment of PPCP-Containing Sewage in an Anoxic/Aerobic Reactor Coupled with a Novel Design of Solid Plain Graphite-Plates Microbial Fuel Cell
Yi-Tang Chang, Chu-Wen Yang, Yu-Jie Chang, Ting-Chieh Chang +1
KI-Zusammenfassung
72 % KonfidenzThis study couples a two-chamber microbial fuel cell (MFC) with an anoxic/aerobic (A/O) reactor using novel solid plain graphite plates (SPGRPs) to treat synthetic sewage containing high-concentration pharmaceuticals (acetaminophen, ibuprofen, sulfamethoxazole at mg/L levels). Over 125 days at 8 h HRT, the system achieved 97.2% COD removal, 83.75% total nitrogen removal, and >98% PPCP removal while generating 532.61 mW/m² maximum power density. Nitrogen cycling involved simultaneous nitrification–denitrification in biofilms, with ammonia removal of 97.96% and nitrate reduction of 83.28% in the anoxic chamber. The proton exchange membrane (PEM) bound ammonia during aerobic nitrification, and coulombic efficiency ranged 2.77–25.20%.
Zentrale Erkenntnisse
Schwellenwert Ammonia concentration increased from 1.767 mg/L influent to 9.021 mg/L in the anoxic reactor due to 100% sludge recycle, then dropped to 0.036 mg/L in effluent, achieving 97.96% NH₄⁺–N removal overall.
Was heißt das. High sludge recycle (100%) creates a localized ammonia spike in the anoxic chamber that must be managed; operators should monitor anoxic NH₄⁺ to avoid inhibition of denitrifiers or excessive nitrification demand downstream.
Zielkonflikt Nitrate removal in the anoxic reactor was 83.28% (1.555 to 0.260 mg/L NO₃⁻–N), but nitrification in the aerobic reactor regenerated nitrate to 1.033 mg/L, indicating incomplete denitrification and re-nitrification cycling.
Was heißt das. The system does not achieve complete nitrogen removal; residual nitrate (1.033 mg/L) in effluent suggests the anoxic HRT (2.04 h) may be insufficient for full denitrification or that electron donor (COD) is limiting in the anoxic zone.
Leistung Power density peaked at 532.61 mW/m² during Phase II (with PPCPs) versus average 285.15 mW/m², and coulombic efficiency ranged 2.77–25.20%, with no significant difference between Phase I (no PPCPs) and Phase II (with PPCPs).
Was heißt das. PPCPs at mg/L levels do not inhibit electricity generation in this MFC design, but the wide EC range (2.77–25.20%) suggests unstable electron recovery; operators should investigate what drives EC variability to improve consistency.
Mechanismus The PEM membrane with sulfonic acid groups bound ammonia during aerobic nitrification, contributing to the 97.96% NH₄⁺–N removal, but this mechanism is not quantified separately from biological nitrification.
Was heißt das. The PEM acts as a passive ammonia trap; designers should consider whether this is a feature (reduces ammonia in effluent) or a liability (ammonia accumulates in the membrane and may need periodic regeneration).
Leistung Nitrite concentrations remained low and stable (0.258–0.408 mg/L NO₂⁻–N across all chambers), with no accumulation despite high nitrification rates, indicating complete oxidation to nitrate or rapid denitrification of nitrite.
Was heißt das. N₂O risk appears low in this system; however, the paper does not measure N₂O directly, so operators should monitor for N₂O emissions if operating conditions shift toward higher DO or lower C/N ratio.
Widersprüche2
Nur Konflikte, die die Publikation selbst zeigt, jeweils am Text geprüft.
Innerhalb der Publikation Anoxic chamber shows both denitrification and ammonia accumulation simultaneously, suggesting conflicting nitrogen transformations.
Eine SeiteAnoxic reactor NH₄⁺–N increased to 9.021 mg/L (from 1.767 mg/L influent) due to sludge recycle
“A significantly increased concentration of NH₄⁺–N was found in the anoxic reactor of 9.02 ± 3.62 mg/L because of the mixing of sewage influent and 100% recycled settlement sludge.”
Andere SeiteAnoxic reactor NO₃⁻–N decreased 83.28% (from 1.555 to 0.260 mg/L), indicating active denitrification
“A removal efficiency of 83.28% for nitrate was measured with a biological reduction from 1.555 ± 0.501 mg/L to 0.260 ± 0.076 mg/L.”
Einordnung der Autoren. Both processes occur in the same anoxic chamber: ammonia is released from sludge hydrolysis/decay while nitrate is simultaneously reduced by denitrifiers. The authors do not explicitly reconcile this; it reflects the complexity of a mixed anoxic environment with both heterotrophic and autotrophic activity.
Innerhalb der Publikation Effluent nitrate concentration (1.033 mg/L) is higher than anoxic reactor effluent (0.260 mg/L), contradicting the expectation that aerobic nitrification should only increase nitrate, not exceed it by 4-fold.
Eine SeiteAnoxic reactor NO₃⁻–N = 0.260 ± 0.076 mg/L (after 83.28% removal)
“A removal efficiency of 83.28% for nitrate was measured with a biological reduction from 1.555 ± 0.501 mg/L to 0.260 ± 0.076 mg/L.”
Andere SeiteAerobic reactor (cathode) NO₃⁻–N = 0.335 ± 0.124 mg/L; final effluent NO₃⁻–N = 1.033 ± 0.670 mg/L
“Nitrification was found to occur in aerobic reactor, where the concentration of nitrate was increased from 0.260 mg/L to 1.033 mg/L.”
Einordnung der Autoren. The authors state nitrification occurs in the aerobic reactor, but the 4-fold increase in nitrate (0.260 to 1.033 mg/L) is larger than expected from ammonia nitrification alone (0.087 mg/L in aerobic reactor). This may reflect measurement variability (high SD: ±0.670 mg/L) or incomplete mixing/sampling, but the paper does not address the discrepancy.
Ansatzpunkte6
Konkrete Lücken in dieser Publikation, jeweils mit einem Experiment, das sie schließen würde.
Hoch N₂O emissions are not measured. Given the high nitrification rates (ammonia drops from 9.021 to 0.087 mg/L in aerobic chamber) and the presence of denitrifiers in biofilms, N₂O production risk is unknown.
Section 3.1 reports near-complete nitrification but provides no N₂O data. The paper states 'Nitrite might be converted to nitrate when the cathodic electrode acts as the electron donor due to denitrification in the MFC' but does not measure N₂O or N₂. N₂O is a potent greenhouse gas and a regulatory concern in nitrogen removal systems.
Versuch. Measure N₂O and N₂ in gas headspace of anoxic and aerobic chambers using GC-ECD or membrane inlet mass spectrometry; vary DO (currently 4.22 ± 0.45 mg/L in aerobic chamber) and anoxic HRT (currently 2.04 h) to map N₂O production window.
Hoch Cathode and anode potentials are not reported. The paper measures voltage across a 1 kΩ external resistance but does not provide individual electrode potentials (vs. Ag/AgCl or SHE), making it impossible to assess whether the cathode is operating in a regime favorable for denitrification or if the anode is limiting.
Section 2.4 and Figure 4 describe power density and coulombic efficiency but no potentiostat data. The authors note 'Direct electron transfer from microbial cells to electrodes occurs at very low efficiency' but do not measure or control electrode potentials. This is critical for understanding whether the MFC is operating as a true bioelectrochemical system or primarily as a biofilm reactor with incidental electricity generation.
Versuch. Install reference electrodes (Ag/AgCl) in both chambers and measure anode and cathode potentials vs. SHE during steady state. Vary external resistance from 1 Ω to 100 kΩ and record potentials to construct a true polarization curve with electrode potentials.
Mittel C/N ratio is not varied. The influent C/N ratio is 257.16:13 (≈19.8:1 by mass), which is higher than the 'best composition' cited (100:5 = 20:1). The paper does not test whether lower C/N ratios (e.g., 10:1 or 5:1) would improve nitrogen removal or reduce residual nitrate in effluent.
Section 2.3 states the C/N ratio is 'quite close to the best composition (C/N/P = 100:5:1)' but does not explore the effect of C/N on nitrogen removal efficiency or on the balance between nitrification and denitrification. The residual nitrate (1.033 mg/L) and incomplete denitrification (83.28%) suggest carbon may not be limiting, but this is not tested.
Versuch. Operate the system at C/N ratios of 5:1, 10:1, 15:1, and 20:1 (by mass) while holding HRT constant at 8 h. Measure NO₃⁻–N, NO₂⁻–N, NH₄⁺–N, and power density to identify the optimal C/N for complete nitrogen removal and electricity generation.
Mittel Anoxic HRT (2.04 h) is not optimized. The paper does not test whether increasing anoxic residence time would improve denitrification (currently 83.28% removal) or reduce the need for sludge recycle.
Section 2.3 states the anoxic HRT is 2.04 h (out of 8 h total), but provides no justification or sensitivity analysis. The 83.28% nitrate removal and residual 0.260 mg/L NO₃⁻–N suggest the anoxic zone may be undersized. The 100% sludge recycle creates a high ammonia spike (9.021 mg/L) that must be nitrified downstream, increasing oxygen demand.
Versuch. Vary anoxic HRT from 1 h to 4 h (by adjusting flow rate or reactor volume) while holding total HRT at 8 h. Measure NO₃⁻–N, NO₂⁻–N, NH₄⁺–N, and denitrification rate to identify the minimum HRT for complete denitrification.
Mittel Dissolved oxygen in the aerobic chamber (4.22 ± 0.45 mg/L) is not controlled or varied. The paper does not test whether lower DO would reduce N₂O production (if any) or whether higher DO would improve nitrification kinetics.
Table 2 reports DO in the aerobic chamber but does not describe aeration control strategy or test the effect of DO on nitrogen removal or electricity generation. The high nitrification rate (ammonia drops from 9.021 to 0.087 mg/L) suggests DO is not limiting, but the paper does not explore the trade-off between nitrification completeness and N₂O emissions.
Versuch. Operate the aerobic chamber at DO setpoints of 1, 2, 4, and 6 mg/L using proportional aeration control. Measure nitrification rate, N₂O emissions, power density, and oxygen transfer efficiency to identify the optimal DO for complete nitrification with minimal N₂O and energy cost.
Niedrig Catholyte pH (7.48 ± 0.31 in aerobic chamber) is not controlled or varied. The paper does not test whether pH affects nitrification kinetics, denitrification, or electricity generation.
Table 2 reports pH but does not describe pH control or test the effect of pH on nitrogen removal. Nitrification is known to be pH-sensitive (optimal 7.5–8.5), and the measured pH (7.48) is at the lower end of the optimal range. The anoxic chamber pH (8.07) is higher, which may favor denitrification.
Versuch. Vary aerobic chamber pH from 6.5 to 8.5 using acid/base dosing and measure nitrification rate, nitrite accumulation, and power density to identify the optimal pH for the coupled system.
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Literatur-Priors
Was gemacht wurde
- Systemtyp
- MFC
Was funktioniert hat
Zusammenfassung
Synthetic sewage containing high concentrations of pharmaceuticals and personal care products (PPCPs, mg/L level) was treated using an anoxic/aerobic (A/O) reactor coupled with a microbial fuel cell (MFC) at hydraulic retention time (HRT) of 8 h. A novel design of solid plain graphite plates (SPGRPs) was used for the high surface area biodegradation of the PPCP-containing sewage and for the generation of electricity. The average COD Cr and total nitrogen removal efficiencies achieved were 97.20% and 83.75%, respectively. High removal efficiencies of pharmaceuticals, including acetaminophen, ibuprofen, and sulfamethoxazole, were also obtained and ranged from 98.21% to 99.89%. A maximum power density of 532.61 mW/cm 2 and a maximum coulombic efficiency of 25.20% were measured for the SPGRP MFC at the anode. Distinct differences in the bacterial community were presented at various locations including the mixed liquor suspended solids and biofilms. The bacterial groups involved in PPCP biodegradation were identified as Dechloromonas spp., Sphingomonas sp., and Pseudomonas aeruginosa . This design, which couples an A/O reactor with a novel design of SPGRP MFC, allows the simultaneous removal of PPCPs and successful electricity production.
Schlagwörter
Kennungen
- Zeitschrift
- BioMed Research International
- Jahr
- 2013
Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.
Berichtete Parameter
Der in der Publikation berichtete Wert (▼) ist auf der Literaturverteilung aus MESS-Parameters eingezeichnet. Werte außerhalb des Bands werden als Ausreißer gekennzeichnet.
7 extrahierte Werte
Extrahierte Werte ansehenÖffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.
Im Labor öffnen →