Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Seasonal variations of pollutants removal and microbial activity in integrated constructed wetland–microbial fuel cell systems
Xiaoou Wang, Yimei Tian
KI-Zusammenfassung
70 % KonfidenzThis study investigated the seasonal variations of pollutants removal and microbial activity in constructed wetland–microbial fuel cell systems (CW–MFCs) and found that temperature significantly influenced bioelectricity generation and removal of organics and nitrogen.
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Literatur-Priors
Was gemacht wurde
- Systemtyp
- MFC
Was funktioniert hat
Zusammenfassung
Abstract This study investigated the seasonal variations of pollutants removal and microbial activity in constructed wetland–microbial fuel cell systems (CW–MFCs). The results showed that the atmospheric temperature significantly influenced the bioelectricity generation and removal of organics and nitrogen in CW–MFCs by primarily influencing the microbial enzymatic activity. The electricity output of CW-MFCs was extremely low below 5 °C, and reached the maximum above 25 °C. The organics and nitrogen removal of closed-circuit CW–MFC reached the highest in summer and autumn, followed by spring, and decreased by an average of 10.5% COD, 14.2% NH3-N and 10.7% TN in winter, demonstrating smaller seasonal fluctuations compared to open-circuit CW–MFC in which the difference between summer and winter was 13.4% COD, 15.1% NH3-N and 15.1% TN. Even at low temperatures, the MFC current could enhance the enzymatic activity and stabilize the growth of microorganisms on the electrodes, moreover, the closed circuit operation can promote the bacteria diversity on CW–MFC anodes as well as the abundance of electrogens on CW–MFC anodes and cathodes, and thus reduce the adverse effect of cooling on organics and nitrogen removal in CWs. However, neither MFC nor temperature had a significant influence on phosphorus removal in CW–MFCs.
Zentrale Ergebnisse
- The electricity output of CW-MFCs was extremely low below 5 °C, and reached the maximum above 25 °C.
- The organics and nitrogen removal of closed-circuit CW–MFC reached the highest in summer and autumn, followed by spring, and decreased by an average of 10.5% COD, 14.2% NH3-N and 10.7% TN in winter.
- The closed circuit operation can promote the bacteria diversity on CW–MFC anodes as well as the abundance of electrogens on CW–MFC anodes and cathodes.
Schlagwörter
Kennungen
- Zeitschrift
- Journal of Water Reuse and Desalination
- Jahr
- 2021
Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.
Berichtete Parameter
Der in der Publikation berichtete Wert (▼) ist auf der Literaturverteilung aus MESS-Parameters eingezeichnet. Werte außerhalb des Bands werden als Ausreißer gekennzeichnet.
3 extrahierte Werte
Extrahierte Werte ansehenÖffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.
Im Labor öffnen →