Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.
Enhanced nitrogen removal of low C/N wastewater using a novel microbial fuel cell (MFC) with Cupriavidus sp. S1 as a biocathode catalyst (BCS1)
Wenying Li, Yuxiang Liu, Lijie Wu, Ruipeng Ren +1
KI-Zusammenfassung
70 % KonfidenzAbstractBACKGROUNDAn innovative microbial fuel cell (MFC) using Cupriavidus sp. S1 as the biocathode catalyst was developed to improve nitrogen removal from low carbon/nitrogen (C/N) wastewater.
Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen
Literatur-Priors
Was gemacht wurde
- Systemtyp
- MFC
Was funktioniert hat
Zusammenfassung
AbstractBACKGROUNDAn innovative microbial fuel cell (MFC) using Cupriavidus sp. S1 as the biocathode catalyst was developed to improve nitrogen removal from low carbon/nitrogen (C/N) wastewater.RESULTSThe desirable external resistance was 100 Ω in this study, with an optimal total nitrogen (TN) removal efficiency of 95.71%, and a maximum current density and power density of 7583.89 ± 318.11 mA m⁻³ and 932 mW m⁻³ at C/N = 2, respectively, which initially confirmed the ability of Cupriavidus sp. S1 to obtain electrons from the electrode. The maximum tolerance of the system at Rext of 100 Ω was C/N = 1, with a TN removal efficiency of 90.87%. Compared with the open circuit, the TN removal increased by approximately 21.60% and 52.02% at C/N = 2 and 1, respectively, which expanded the application area for the dominant denitrifying bacteria S1. Additionally, the system exhibits the obvious merits of less sludge production, low energy consumption and the recovery of some energy.CONCLUSIONBased on these results, domesticated Cupriavidus sp. S1 possesses electrochemical activity. Thus, the system has great potential for efficient and cost‐effective nitrogen removal from nitrate‐containing low C/N wastewater and energy recovery. © 2019 Society of Chemical Industry
Zentrale Ergebnisse
- S1 as the biocathode catalyst was developed to improve nitrogen removal from low carbon/nitrogen (C/N) wastewater.
- 71%, and a maximum current density and power density of 7583.
- 11 mA m⁻³ and 932 mW m⁻³ at C/N = 2, respectively, which initially confirmed the ability of Cupriavidus sp.
- 87%.
- Compared with the open circuit, the TN removal increased by approximately 21.
Schlagwörter
Kennungen
- Zeitschrift
- Journal of Chemical Technology & Biotechnology
- Jahr
- 2020
Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.
Berichtete Parameter
Der in der Publikation berichtete Wert (▼) ist auf der Literaturverteilung aus MESS-Parameters eingezeichnet. Werte außerhalb des Bands werden als Ausreißer gekennzeichnet.
8 extrahierte Werte
Extrahierte Werte ansehenÖffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.
Im Labor öffnen →