Forschungsdaten – Titel und Zusammenfassungen von Publikationen, extrahierte Daten und Katalogeinträge – erscheinen in ihrer Originalsprache Englisch.

KI-Zusammenfassung

75 % Konfidenz

An integrated bubble column reactor-microbial fuel cell (BCR-MFC) was developed for simultaneous aerobic toluene vapor biodegradation, nitrification, heterotrophic denitrification, and electricity generation, achieving a maximum elimination capacity of 248 g m⁻³ h⁻¹ and a power density of 4.8 W m⁻³.

Erstellt von der MESSAI-Extraktionspipeline · mit dem Quell-PDF abgleichen

Was gemacht wurde

Systemtyp
MFC

Was funktioniert hat

Leistungsdichte4800mW/m²

Zusammenfassung

An integrated bubble column reactor-microbial fuel cell (BCR-MFC) was developed for simultaneous aerobic toluene vapor biodegradation, nitrification, heterotrophic denitrification, and electricity generation. The BCR-MFC was tested under various inlet loading rates (ILRs) of toluene to the bio-cathode chamber. The maximum elimination capacity (EC max ) reached 248 g m -3 h -1 at an ILR of 456 g m -3 h -1 . Optimal performance occurred at an ILR of 306 g m -3 h -1 , yielding an EC of 208 g m -3 h -1 and a voltage output of 522 mV based on the integrated efficiency parameter (ε). The highest power density (4.8 W m -3 ) was obtained at the lowest ILR (70 ± 6 g m -3 h -1 ). At an ILR of 316 ± 30 g m -3 h -1 , NH₄ + -N decreased from 1.3 g L -1 to 0.134 g L -1 , and NOₓ - -N from 1.3 g L -1 to 0.239 g L -1 . Microbial community analysis revealed increased abundance of toluene-degrading bacteria, heterotrophic denitrifiers, and nitrifiers, including Pseudomonas, Paracoccus, Zoogloea, and Bacillus. These results highlight the BCR-MFC ability to couple efficient toluene degradation with nitrogen compound removal while producing bioelectricity, facilitated by the coexistence of essential microbial species in the bio-cathode chamber.

Schlagwörter

Microbial fuel cellTolueneHeterotrophMicrobial population biologyNutrientElectricity generation

Kennungen

PubMed
41138672
Zeitschrift
Bioelectrochemistry (Amsterdam, Netherlands)
Jahr
2025
Generische MFCRepräsentatives Modell
Klicken, um die Strömung zu animieren
3D-Modell wird geladen …

Repräsentatives Modell: MFC – zugeordnet nur anhand des Systemtyps der Publikation, nicht ihres Reaktors oder ihrer Geometrie.

Extraktion

Berichtete Parameter

Öffnen Sie das Modell im Labor, um alle Steuerelemente, die Parameterbearbeitung und Vorlagen-Overlays zu nutzen.

Im Labor öffnen →